Karahan, A.*; 川田 賢一; Tentner, A.*
Proceedings of 2018 ANS Winter Meeting and Nuclear Technology Expo; Embedded Topical International Topical Meeting on Advances in Thermal Hydraulics (ATH 2018) (USB Flash Drive), 4 Pages, 2018/11
An initial comparison of the SAS4A version 5.2 code predictions and observed results of two of the CABRI-1 Sodium-cooled Fast Reactor (SFR) Oxide Fuel tests has been accomplished. The selected experiments are (1) AI3, a Transient Over-Power test and (2) BI3, a Loss-of-Flow and Transient Over-Power test. The initial simulations describe the test events up to the time of cladding failure and results such as onset of the coolant boiling, time and spatial variation of the fuel pin temperature, and clad failure time and location are given. The calculated clad failure results are in reasonable agreement with the corresponding experimental results. Directions for further improvement of the mixed oxide fuel models of the SAS4A code are outlined.
深野 義隆; 今泉 悠也; 吉岡 尚憲*; 赤堀 央*
no journal, ,
ナトリウム冷却高速炉の炉心損傷起因過程解析コードSAS4Aを用いて、国際共同CABRI炉内試験の解析を実施した。本研究では、いずれも中程度の燃焼度でスミア密度の低い燃料を用い、出力パルスの印加タイミングの異なる3試験を対象に試験解析を行った。本発表では、SAS4Aコードのモデル概要、及び解析の対象としたCABRI炉内試験の概要について説明し、後続の発表で各試験の解析結果について報告する。
赤堀 央*; 深野 義隆
no journal, ,
本研究では、炉心損傷起因過程解析コードSAS4Aを用いて、国際共同CABRI炉内試験のうち、流量減少の後、冷却材沸騰前に出力パルスを印加したLTX試験の解析を行った。SAS4Aコードによる試験解析の結果、過渡時の冷却材温度変化及び過渡後の燃料ピン破損後の燃料の溶融移動等について、試験結果とほぼ一致することを確認した。
吉岡 尚憲*; 深野 義隆
no journal, ,
本研究では、炉心損傷起因過程解析コードSAS4Aを用いて、国際共同CABRI炉内試験のうち、流量減少の後、冷却材沸騰前に出力パルスが印加されたLT4試験の解析を行った。SAS4Aコードによる試験解析の結果、過渡時の冷却材温度変化及び過渡後の燃料ピン破損後の燃料の溶融移動等について、試験結果と良好な一致を確認した。